EMGZ491.PNET – Single-Channel Amplifier for PROFINET IO
- PROFINET IRT- or RT-Device
- Configuration via PROFINET IO or web interface
- Communication cycle time ≥ 0.5 ms (IRT)
- Various installation options
The EMGZ 491.PNET amplifier has been designed for use in modern PROFINET IO networks where a typical application involves the measurement or control of web tension in coating, laminating, printing, extrusion, or other similar roll to roll processes. Making full use of the PROFINET IO capabilities allows this amplifier to excel in high speed applications. An extensive range of parameters allows for quick and flexible configuration of the unit, and all functions are easily adjusted via PROFINET IO with an IO-controller.
General technical details
Number of channels | 1 |
---|---|
Number of force sensors | 1 to 2 |
Processor cycle time | 0,5 ms |
Voltage output | -10 to 10 VDC, min. 1000 Ω, 12 bit |
Current output | none |
Digital inputs | none |
Relay output | none |
Power supply | 24 VDC (18 to 36 VDC) |
Available variants
Bild | Name | Sensor feedback signal | Temperature range | Housing | Protection class | CAD data | Watchlist |
---|---|---|---|---|---|---|---|
EMGZ491.R.PNET | ± 9 mV (max. ± 11.25 mV) | -10 to 50 °C (14 to 122 F) | DIN-rail mount | IP 20 | PDF DWG STP | ||
EMGZ491.R.V05.PNET | ± 2.5 mV (max. ± 3.125 mV) | -10 to 50 °C (14 to 122 F) | DIN-rail mount | IP 20 | PDF DWG STP | ||
EMGZ491.W.PNET | ± 9 mV (max. ± 11.25 mV) | -10 to 50 °C (14 to 122 F) | wall mount | IP 65 | PDF DWG STP | ||
EMGZ491.W.V05.PNET | ± 2.5 mV (max. ± 3.125 mV) | -10 to 50 °C (14 to 122 F) | wall mount | IP 65 | PDF DWG STP |
Your benefits
- Simple integration into PROFINET networks
- Easy configuration with parameter sets for demanding applications
- Fast and precise – well suited for time-critical applications
- Narrow DIN rail version for cabinet or sealed IP 65 wall mount for harsh environment. RJ45/M12 plugs and detachable term
Features
- PROFINET IRT- or RT-Device
- Configuration via PROFINET IO or web interface
- Communication cycle time ≥ 0.5 ms (IRT)
- Various installation options
Industry